Setting⑯ : Mono Mode - Mitsubishi Electric KD Series User Manual

Contact image sensor, web surface inspection
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

5-2 Setting⑯: Mono mode Setting
Address
Register name
7110h MonoModeSelect
5-2-18 Mono mode Setting
[Function]
Select and switch a type of output image data when output
format when you set Output format to be Mono mode.
Output data : Red , Green or Blue pixel output,
Luminance value output
Luminance value=77/256×R+150/256×G+29/256×B
[Remark]
When you select RGB color mode and set
"MonoModeSelect=1" (Luminance value), each of R, G,
and B pixels outputs becomes the above value, providing
monochrome image.
TM-XJ959A
R/W
Parameter
Data
Select Mono mode
(This function can change the output of RGB color mode.)
Mono mode 0: Green pixel output, 1: Luminance value output
R/W
0 to 3
RGB color mode 0: Color output, 1: Luminance value output
Function
2:Red pixel output, 3:Blue pixel output
2: prohibit selection, 3: prohibit selection
Initial
0