5-2 Setting⑤: Output Clock Frequency Setting
Address
Register name
R/W
CameraLink
6008h
R/W
Clock_Select
5-2-7 Output Mode Setting
[Function]
Switch output clock frequency of Camera Link®
Relationship of parameter data vs. clock frequency.
Clock Frequency
Parameter Data
Parameter Data
(MHz)
0 (0x00)
48.0
11 (0x0B)
1 (0x01)
50.7
12 (0x0C)
2 (0x02)
51.0
13 (0x0D)
3 (0x03)
51.4
14 (0x0E)
4 (0x04)
52.0
15 (0x0F)
5 (0x05)
52.8
16 (0x10)
6 (0x06)
53.3
17 (0x11)
7 (0x07)
54.0
18 (0x12)
8 (0x08)
54.9
19 (0x13)
9 (0x09)
56.0
20 (0x14)
10 (0x0A)
57.0
21 (0x15)
TM-XJ959A
Parameter
Data
Switch Camera Link® output clock frequency
0 to 28
Refer to below tables for relationship of parameter vs.
clock frequency.
Clock Frequency
Clock Frequency
Parameter Data
(MHz)
(MHz)
57.6
22 (0x16)
72.0
58.3
23 (0x17)
76.0
60.0
24 (0x18)
76.8
61.7
25 (0x19)
78.0
62.4
26 (0x1A)
80.0
64.0
27 (0x1B)
81.6
65.1
28 (0x1C)
84.0
66.0
67.2
68.0
68.6
Camera Link® is a trade mark registered by AIA(Automated Imaging Association).
Function
【Remark】
1) When changing CameraLinkClock_Select, this is
reflected including slave channel.
2) Because "Output Mode Setting" interacts with Line
Frequency and number of output pixel, please set this
setting based on your calculation for each setting.
3) Set to 28 if inputting invalid parameter data
(more than 28).
Initial
28
72
© Mitsubishi Electric Corporation