11.3.5

Technical Specifications

Table 11-9
Technical data
Control Supply Module
Input data
Line voltage
Line frequency
Rated input current
Rated value (at U
)
eRated
Starting current inrush
Power loss ride-through (at 400 V
DC link voltage
Supply current (at 600 V)
Output data
Output voltage
Rated output current
Startup to short-circuit
Short-circuit during operation
24 V DC busbar
current carrying capacity
Residual ripple (clock frequency approx.
50 kHz)
Cycle peaks (bandwidth 20 MHz)
Power loss
1
Weight
1 For an overview, see the power loss tables in chapter Cabinet Design
Booksize cold-plate power units
Manual, (GH4), 03.2007, 6SL3097-2AJ00-0BP4
Unit
V
AC
Hz
A
AC
A
AC
)
ms
AC
V
DC
A
DC
V
DC
A
DC
A
DC
A
DC
A
DC
mV
pp
mV
pp
W
kg
Value
3-ph. 380 - 480 V
± 15 %
AC
47 to 63
approx. 2
Max. 80
5
430 to 882 (300 to 430 < 1 min)
1,1
26 +/- 2 %
20
≤ 24
Normally 23 (continuous)
20
< 100
< 200
< 105
4,8
DC link components