No.F002 Fire Extinguishing System Conceptual Diagram 2
-
+
+
ROV
SIL
AL
FLT
RST
E
AUX
REMOTE
24V
CONTROL
Technical requirements:
1.
All fire extinguishing signal cables are red (BOM number: 25030029) and black (BOM number: 25030073) cables with naked crimping single-wire cord end terminals (BOM number: 14170214). The red cable is positive and the black cable is
negative. The pneumatic switch, warning signs, and fire alarm bell each has two wiring terminals that connect to two wires. The fire alarm bell is polarity insensitive. For details, see the diagram.
2. Connect a 10 K terminal resistor to each of the last the fire alarm sounder and fire alarm horn/strobe in parallel.
3. Connect cables to the smoke detector and heat detector by referring to the diagram. Connect a 6.8 K terminal resistor to the last smoke and heat detectors in parallel.
4. Connect the emergency abort button and pneumatic switch to a 6.8 K terminal resistor in parallel, and to a 470 ohm resistor in serial. Connect an electrical actuator to a 1N4004 diode in parallel.
5. Alarm signals are reported to the monitoring system over shielded straight-through network cables. The connection definitions are as follows: LOCAL FIRE, FIRE RELAY, and FAULT RELAY. The signal cables connect to
the ECC over dry contacts.
6. Attach cable labels to all cables connected to the extinguishant control panel and wiring terminals on electrical actuators and pneumatic switches. See the label table for the label content. Cable direction labels must be
arranged neatly in the same direction. Cables must be bound neatly, with cable ties in the same direction. (Labels are printed on label paper with the BOM number 29041061, attached on cable ties with the BOM number
21200708, and bound to corresponding cables.)
Smoke Detector-B3
Smoke Detector-B2
Smoke Detector-B1
red
red
L1 IN
L1 IN
L1 IN
-R
-R
red
red
L1 OUT
L1 OUT
L1 OUT
L1 OUT
L2
L2
L2
black
black
black
black
Heat Detector-B3
Heat Detector-B2
red
red
L1 IN
L1 IN
-R
-R
red
red
L1 OUT
L1 OUT
L2
L2
black
black
black
black
red
black
red
black
+
-
+
-
+
-
+
-
+
-
+
-
+
-
+
-
NC
C
DATA
POWER
S1
S2
ZONE 1
ZONE 2
ZONE 3
2ND
1ST
SOUNDER
STAGE
STATUS UNITS
Data cable
Power cable
Connect the first stage alarm to
Connect smoke detector in
Connect heat detector in
the fire alarm bell.
Connect the second stage alarm to the horn strobes and
detection zone 1
detection zone 2
warning signs .
-R
Heat Detector-B1
L1 IN
-R
L1 OUT
L1 OUT
L2
NO
NC
C
NO
+
-
+
-
+
-
+
-
+
-
+
-
NO
C
NC
2ND
MODE
MAN
HOLD
REL
EXTING
LOW
EXTRACT
STAGE
SELECT
RELEASE
PRESS
PRESS
SWITCH
SWITCH
Connect the
Connect the pressure
Connect the electrical
Connect the fault signal
emergency
actuator drive signal to the
signal to the pneumatic
output (NO) to the collector of
electrical actuator.
abort port to
switch.
the monitoring system.
the Extinguishant
abort button .
To Monitoring system
brown & white
green
brown & white
green
green
brown & white
C
NO
NC
C
NO
NC
C
NO
FAULT
LOCAL
FIRE
RELAY
FIRE
RELAY
Connect the gas release signal
Connect the fire alarm signal
output (NO) to the collector of
output (NO) to the collector of
the monitoring system.
the monitoring system.