Conveyor Chain (Fl At Top Chain/Accumulation Roller Chain) - Bosch Rexroth BS 2/C Series Assembly Instructions Manual

Belt sections
Hide thumbs Also See for Rexroth BS 2/C Series:
Table of Contents

Advertisement

)
*
Flat top chains
Fig. 18: Lubrication points
10.3.4
Conveyor chain (fl at top chain/accumulation roller chain)
The conveyor chain used in this product has already been lubricated at the factory
before delivery.
Before commissioning for the fi rst time, lubricate the conveyor chain with 1 to 2 g
oil per chain meter, and afterwards every 1000 operating hours with 2 to 3 g oil/m,
using Structovis GHD (0 842 904 229).
For system-related reasons, the lubricant can spread.
)
*
Accumulation roller chain
*) Also lubricate the fl at top chain on the side (in curves and sections).
NOTE!
Always comply with the maintenance intervals, as a lack of lubrication will result
in operational disruptions due to a chain malfunction, up to a system crash with
substantial damage to property.
Maintain a maintenance schedule.
The running times during set-up and commissioning of the system count as a part
of the fi rst maintenance interval.
If you do not know how long the system ran during set-up and commissioning,
lubricate the conveyor chain before starting production.
Lubricate the chain after downtimes > 6 months (e.g. if set-up took a very long
time or if the system was temporarily decommissioned).
Before lubricating the chain, clean off any excess grease, dirt, or other
contamination. While doing so, also check the conveyor chain for wear and
elongation.
We recommend: The LU 2 automatic lubrication unit enables an optimally
defi ned, uniform lubrication of the conveyor chain during operation.
See page 41.
Maintenance and Repair
Vplus accumulation roller chain
3 842 358 724/2013-04, MIT: BS 2/C-... + BS 2/R-..., Bosch Rexroth AG
39/76