56/76
Maintenance and Repair
)
*
Flat top chains
Fig. 39: Lubrication points
Bosch Rexroth AG, MIT: BS 2/C-... + BS 2/R-..., 3 842 358 724/2013-04
10.4.14 Notes for mounting: Direction of movement of the chain
Conveyor chain malfunction
(fl at top chain/accumulation roller chain with small parts trap)
Operation of the chain against the direction of movement will lead to conveyor
chain malfunctions and can lead to a crash. There is a danger of damage to property
Make sure that the chain is mounted in its correct direction of movement.
Flat top chains
Fig. 38: Direction of movement of the chain
10.4.15 Notes for mounting: Lubrication points
Conveyor chain malfunction (fl at top chain/accumulation roller chain)
Lack of lubrication on the conveyor chain will lead to conveyor chain malfunctions
and can lead to a crash. There is a danger of damage to property.
The conveyor chain used in this product has already been lubricated at the
factory before delivery.
Before commissioning, lubricate the conveyor chain with 1 to 2 g oil per chain
meter, and afterwards every 1000 operating hours with 2 to 3 g oil/m,
using Structovis GHD, 0 842 904 229.
)
*
Accumulation roller chain
*) Also lubricate the fl at top chain on the side (curves and sections)
For system-related reasons, the lubricant can spread.
NOTICE
Accumulation roller chain with small parts trap
NOTICE
Vplus accumulation roller chain