Control Of Hydraulic Drifts - Analysis Of The Causes; Of A Drift - Komatsu PC20R-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC20R-8:
Table of Contents

Advertisement

TESTING AND ADJUSTMENTS

CONTROL OF HYDRAULIC DRIFTS - ANALYSIS OF THE CAUSES

OF A DRIFT

H Test conditions:
Machine: in the conditions indicated in the NOR-
.
MAL TECHNICAL DATA.
Engine: at working temperature.
.
Hydraulic oil: 45 ± 55 ëC.
.
1. Test
To check on the extent of the hydraulic drifts of
individual components and the total hydraulic
drift, position the machine and follow the proce-
dures indicated in the «NORMAL TECHNICAL
DATA».
2. Analysis of the causes of hydraulic drifts
Before disconnecting the tubes, release hydrau-
lic pressures in the circuits (see «ELIMINATION
OF THE RESIDUAL PRESSURES»).
1. Boom test
1 - Position the machine with the arm vertical and
with the back of the bucket resting on the ground.
2 - Stop the engine and release the residual hydrau-
lic pressures.
3 - Disconnect the hoses (1) and (2) that supply the
cylinder on the head side and on the base side.
4 - Plug the two hoses to prevent entry of impurities.
5 - Plug the rigid tube (3) that supplies the cylinder
on the base side.
6 - In order to catch any oil leakages, attach a tube
to the pipe (4) that supplies the head side of
the cylinder.
7 - Start the engine and extend the arm completely.
8 - Stop the engine and check the position of the
boom for 15 minutes.
If the boom moves downwards the drift is due
.
to the cylinder gaskets.
If the boom does not move, the drift is due to
.
the control valve.
20-54
CONTROL OF HYDRAULIC DRIFTS -
ANALYSIS OF THE CAUSES OF A DRIFT
1
4
2
3
RKPA2470
RKP04990
PC20R-8 PC27R-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc27r-8F30791F31103

Table of Contents