Gateways
6.4 SIMATIC RTLS4430G
Error detection
The yellow LED (RADIO) is off.
The blue LED (LAN/SERVER) is off.
The blue LED (LAN/SERVER) is flash‐
ing.
6.4.2
Installation & Operation
6.4.2.1
Notes on installation
Before you install the devices, read this section carefully to ensure trouble-free installation and
operation.
The devices can only be used in conjunction with the RTLS localization system. Setup,
installation and use of the tools and clients of the RTLS localization system are described in the
corresponding manuals.
The device is intended for fixed installation on walls or ceilings. Installation is to be performed
by qualified and trained personnel according to the operating instructions. In addition,
installation must take place in accordance with the respective instructions for the installation of
electrical systems and utilities. The devices must be installed so that they are accessible for
future maintenance, e.g., for opening the enclosure cover.
Note the specifications in the section "Technical specifications" during installation and
operation. Ensure that all screws are securely and firmly screwed into the wall / ceiling and can
support the weight of the device and its wiring.
Make sure that the ambient temperature does not exceed 60 °C and that the device is not
installed at a location where it is exposed to direct sunlight.
Connection of the cables
Make sure that the Twist-Lock connectors are inserted correctly to prevent moisture from
entering the enclosure.
Make sure that the wiring is correct before you start up the device.
Only use the cables described in the manual, supplied with the device or otherwise prescribed.
SIEMENS AG is not liable for damages or functional limitations caused by the use of other
cables.
Protect the device from penetrating moisture by closing off connectors that are not in use with
suitable covers. These covers are installed on the device.
Supply voltage
When the supply voltage is connected to the power plug, all LEDs flash briefly for a moment.
The POWER LED lights up as soon as voltage is present.
114
Cause of the error
Device is not connected to the Locating
Manager.
Device has no network connection
(LAN)
Device is not connected to the Locating
Manager.
Troubleshooting
Switch on Locating Manager.
Check local network, check firewall
Activate Locating Manager