Mitsubishi Electric MELSEC-Q Structured Programming Manual page 154

Hide thumbs Also See for MELSEC-Q:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
[Device & Common]
Number and name
RS2 instruction [ch1] (Refer to the data communication manual for details.)
[M]8400
Unavailable
*1
RS2[ch1] Send wait flag
[M]8401
*1
RS2[ch1] Send request
M 8402
*1
RS2[ch1] Receive complete flag
M 8403
[M]8404
RS2[ch1] Carrier detection flag
[M]8405
RS2[ch1] Data set ready (DSR) flag
[M]8406
[M]8407
Unavailable
[M]8408
M 8409
RS2[ch1] Timeout check flag
*1.
They are cleared when the PLC mode switches from RUN to STOP or when the RS2 instruction [ch1]
is set to OFF.
*2.
Available in Ver. 2.30 or later.
RS2 instruction [ch2] and computer link [ch2] (Refer to the data communication manual for details.)
[M]8410 to [M]8420
Unavailable
*3
RS2[ch2] Send wait flag
[M]8421
*3
RS2[ch2] Send request
M 8422
*3
RS2[ch2] Receive complete flag
M 8423
[M]8424
RS2[ch2] Carrier detection flag
[M]8425
RS2[ch2] Data set ready (DSR) flag
[M]8426
Computer link [ch2]: Global signal ON
[M]8427
Computer link [ch2]: On-demand send being executed
M 8428
Computer link [ch2]: On-demand error flag
Computer link [ch2]: On-demand word/byte changeover
M 8429
RS2 (FNC87) instruction [ch2]: Timeout check flag
*3.
They are cleared when the PLC mode switches from RUN to STOP or when the RS2 instruction [ch2]
is set to OFF.
*4.
Available in Ver. 2.30 or later.
Number and name
MODBUS serial communication [ch1] (Refer to MODBUS serial communication Manual for details.)
[M]8401
MODBUS Request in Process
[M]8402
MODBUS Communication Error
[M]8403
MODBUS Communication Error (latched)
[M]8404
Listen Only Mode
[M]8405 to [M]8407
Unavailable
[M]8408
Retry
[M]8409
Timeout
[M]8410
Unavailable
MODBUS serial communication [ch2] (Refer to MODBUS serial communication Manual for details.)
[M]8421
MODBUS Request in Process
[M]8422
MODBUS Communication Error
[M]8423
MODBUS Communication Error (latched)
[M]8424
Listen Only Mode
[M]8425 to [M]8427
Unavailable
[M]8428
Retry
[M]8429
Timeout
[M]8430
Unavailable
MODBUS serial communication [ch1, ch2] (Refer to MODBUS serial communication Manual for details.)
M 8411
MODBUS Configuration Request Flag
*5.
Available in Ver. 2.40 or later.
*6.
Available in Ver. 1.30 or later.
152
4 Operations of Special Devices (M8000 and later, D8000 and later)
Operation and function
Operation and function
4.1 Special Device List (M8000 and later, D8000 and later)
Applicable model
FX
FX
FX
FX
3U
3UC
3G
-
-
-
*2
*2
-
-
-
-
-
-
-
-
-
-
-
-
*4
*4
Applicable model
FX
FX
FX
FX
3U
3UC
3G
*5
*5
*6
*5
*5
*6
*5
*5
*6
*5
*5
-
-
-
-
*5
*5
*6
*5
*5
*6
-
-
-
*5
*5
*6
*5
*5
*6
*5
*5
*6
*5
*5
-
-
-
-
*5
*5
*6
*5
*5
*6
-
-
-
*5
*5
*6
Corresponding
FX
3GC
3S
special device
-
-
-
-
D8402
D8403
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D8422
-
D8423
-
-
-
-
-
-
D8427
D8428
-
D8429
-
Corresponding
FX
3GC
3S
special device
-
D8402
D8403
-
-
-
-
-
-
-
-
-
-
-
-
-
-
D8422
-
D8423
-
-
-
-
-
-
-
-
-
-
-
-
-
-