Mitsubishi Electric MELSEC-Q Structured Programming Manual page 194

Hide thumbs Also See for MELSEC-Q:
Table of Contents

Advertisement

FXCPU Structured Programming Manual
[Device & Common]
Number and name
Interrupt program
D 8393
Delay time
[D]8394
Unavailable
Symbolic information storage status and execution
program protection status using the block
password.
Value
[D]8395
Symbolic Information,
H∗∗00
Block password status
H∗∗01
H∗∗10
H∗∗11
[D]8396
CC-Link/LT setting information
[D]8397
Unavailable
Ring counter
D 8398
Low order
D 8399
High order
*1.
"**" indicates areas used by the system.
*2.
Available in Ver. 3.00 or later.
*3.
Only the FX
*4.
1 ms ring counters (D8399 and D8398) are activated when the END instruction is executed after
M8398 turned ON.
192
Content of register
Symbolic
information storage
execution program
*1
None
*1
None
*1
Provided
*1
Provided
Up-counting ring counters
2,147,483,647 (Unit: 1 ms)
-32MT-LT-2 is available.
3UC
4 Operations of Special Devices (M8000 and later, D8000 and later)
4.1 Special Device List (M8000 and later, D8000 and later)
FX
FX
3U
-
Protection of
*2
None
Provided
None
Provided
-
-
*4
of 0 to
Applicable model
FX
FX
FX
3UC
3G
3GC
3S
-
-
-
-
-
-
-
*2
-
-
-
*3
-
-
-
-
-
-
-
Corresponding
special device
M8393
-
-
-
-
M8398

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-lMelsec-fFx3sFx3gFx3gcFx3u ... Show all

Table of Contents