SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual
Cable Specifications
Cable Type
PV cable that meets the
1500 V standard
Cables with high rigidity, such as armored cables, are not recommended, because
poor contact may be caused by the bending of cables.
Procedure
● Use the MC4 EVO2 PV connectors delivered with the inverter. If the PV
connectors are lost or damaged, purchase the connectors of the same model.
The device damage caused by incompatible PV connectors is beyond the
warranty scope.
● For models of the crimping tool and removal wrench, use the recommended
model or contact your Staubli dealer.
Step 1 Install the DC input power cable.
Issue 07 (2021-07-08)
Scenario
Model of Y-
branch
Connector
(Part A)
Connecting
Models
Y-branch
recommended
connectors
by Huawei
to the
Other models
SUN2000
NO TICE
NO TICE
Copyright © Huawei Technologies Co., Ltd.
Connection Description
Part A can be directly connected to the
SUN2000, and part B is not needed.
To ensure that the terminals of part A
match the DC terminals of the SUN2000,
part B is needed to connect part A to the
SUN2000. Use the DC terminals delivered
with the SUN2000 to connect part B to the
SUN2000.
Conductor Cross-
sectional Area (Unit:
2
mm
)
4–6
5 Electrical Connections
Cable Outer Diameter
(Unit: mm)
4.7–6.4