Huawei SUN2000 Series User Manual page 59

Hide thumbs Also See for SUN2000 Series:
Table of Contents

Advertisement

SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual
● Before turning on the AC switch between the inverter and the power grid,
check that the AC voltage is within the specified range using a multimeter.
● If the solar inverter has not been running for more than half a year after being
mounted, it must be checked and tested by professionals before being put into
operation.
Procedure
Step 1 Turn on the AC switch between the inverter and the grid.
If you perform
shutdown. The inverter can start normally after the fault is automatically cleared.
Step 2 Set DC SWITCH 1 (MAIN SWITCH) at the bottom of the SUN2000 chassis to ON.
Step 3 Check the status of LED 1. If it is steady green, set DC SWITCH 2 and DC SWITCH
3 to ON.
----End
Issue 07 (2021-07-08)
NO TICE
NO TICE
Step 2
before
Copyright © Huawei Technologies Co., Ltd.
Step
1, the inverter reports a fault about abnormal