Huawei SUN2000 Series User Manual page 69

Hide thumbs Also See for SUN2000 Series:
Table of Contents

Advertisement

SUN2000-(196KTL-H0, 200KTL-H2, 215KTL-H0)
Series
User Manual
Figure 7-9 Feature parameters (advanced user)
----End
Parameters
No.
Parameter
1
MPPT multi-peak
scanning
2
MPPT multi-peak
scan interval (min)
3
RCD enhancement
Issue 07 (2021-07-08)
Description
When the inverter is used in
scenarios where PV strings are
greatly shaded, set this parameter
to Enable, and then the inverter
will perform MPPT scanning at
regular intervals to locate the
maximum power.
Specifies the MPPT scanning
interval.
RCD refers to the residual current
of the inverter to the ground. To
ensure device and personal safety,
RCD should be limited to the
specified value in the standard. If
an AC switch with a residual
current detection function is
installed outside the inverter, this
function should be enabled to
reduce the residual current
generated when the inverter is
running, thereby preventing the
AC switch from misoperations.
Copyright © Huawei Technologies Co., Ltd.
7 Man-Machine Interactions
Remarks
-
This parameter is displayed
when MPPT multi-peak
scanning is set to Enable.
-
62

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

196ktl-h0200ktl-h2215ktl-h0Sun2000-196ktl-h0Sun2000-200ktl-h2Sun2000-215ktl-h0 ... Show all