Testing Blowby Pressure - Komatsu PC88MR-10 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC88MR-10:
Table of Contents

Advertisement

30 Testing and adjusting
Engine and cooling system

Testing blowby pressure

a Testing tools
Sym-
Part No.
bol
799-201-1504 Blowby checker
1
2 799T-201-3210 Plug
E
3 799T-201-3220 Cap
Place the machine on a level ground and
lower the work equipment to the ground.
a Check this item under the following conditions.
Coolant temperature: 75 to 94°C
Hydraulic oil temperature: 45 to 55°C
Testing
(PC88MR-A000-36C-K-00-A)
1. Open the engine hood.
2. Loosen clamp (1).
3. Disconnect KCCV gas outlet hose (2), block the
hose by using plug E2, and block KCCV hose
insertion pipe by using cap E3.
4. Loosen clamp (3).
5. Disconnect KCCV gas inlet hose (4), block
KCCV hose insertion pipe by using cap E3,
install tool and adapter [1] of the blowby checker
to hose (4), and connect gauge [2].
6. Start the engine, and set the working mode to
power mode (P).
7. Measure the blowby pressure when the
hydraulic relief is made by arm IN operation at
engine high idle.
a Read the blowby gas pressure when the
gauge pointer stands still.
30-14
(PC88MR-A000-360-K-02-A)
Part name
8. After finishing the measurement, remove the
testing tools, and restore the machine.
PC88MR-10