Failure Code [D110Kb] Battery Relay Output Short Circuit - Komatsu PC88MR-10 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC88MR-10:
Table of Contents

Advertisement

40 Troubleshooting
Troubleshooting by failure code (Display of code)

Failure code [D110KB] Battery Relay Output Short Circuit

Action level
Failure code
L01
D110KB
Detail of
Abnormal current flows when outputting 24 V to battery relay primary circuit (coil side).
failure
Stops 24 V output to battery relay primary circuit (coil side).
Action of
Even if cause of failure disappears, machine does not become normal until starting switch
controller
is turned to OFF position.
Problem on
Each controller may fail in writing of data into its ROM (non-volatile memory).
machine
As T-adapter for pump controller connector is "socket-type box", operating voltage cannot
be measured at pump controller connector.
Related
Method of reproducing failure code: Turn starting switch to ON position, then turn it to
information
OFF position.
No.
Cause
Defective battery relay
1
(Internal short circuit)
Ground fault in wiring harness
2
(Contact with ground circuit)
Pump controller is defective.
3
40-246
Battery Relay Output Short Circuit
Failure
(Pump controller system)
Procedure, measuring location, criteria, and remarks
1. Turn starting switch to OFF position.
Continuity Between terminals R01 and R02
1. Turn starting switch to OFF position.
2. Turn battery disconnect switch to OFF position (to prevent short
circuit during work).
3. Disconnect terminals R01 and R02, and disconnect connectors D01,
H15, and CP02.
Between terminal R02 (BR) and ground
Resis-
Between ground and terminal CP02 (female)
tance
(108), R02 (harness side), D01 (female) (1) or
(2)
If no failure is found by above checks, pump controller is defective.
Reference
1. Turn starting switch to OFF position.
2. Insert T-adapters into connector D01.
3. Turn starting switch to ON position.
4. Measure voltage within 0.5 second after turning staring switch to
OFF position from ON position.
Voltage
Between D01 (1) and ground
(PC88MR-D110KB-400-A-Z0-A)
Continuity
Min. 1 Mz
Min. 1 Mz
20 to 30 V
PC88MR-10

Advertisement

Table of Contents
loading