Failure Code [Dhsqma] Boom Swing Rh Ppc Press Sensor Abnormality - Komatsu PC88MR-10 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC88MR-10:
Table of Contents

Advertisement

Failure code [DHSQMA] Boom Swing RH PPC Press Sensor
Abnormality
(PC88MR-DHSQMA-400-A-Z0-A)
Action level
Failure code
DHSQMA
L01
Detail of
Signal voltage of boom swing RH PPC pressure sensor circuit is below 0.3 V or above 4.5
failure
V.
Sets boom swing RH PPC pressure to 0 MPa {0 kg/cm
Action of
If cause of failure disappears, machine becomes normal by itself.
controller
Automatic deceleration does not cancel.
Problem on
Controllability of boom swing RH deteriorates.
machine
a If 5 V circuit (3) and ground circuit (1) of pressure sensor are connected inversely,
pressure sensor will be broken. Accordingly, take extreme care when checking.
As T-adapter for pump controller connector is "socket-type box", operating voltage cannot
Related
be measured at pump controller connector.
information
Boom Swing RH PPC pressure can be checked with monitoring function.
(Code: 07901 Boom Swing RH PPC pressure)
Method of reproducing failure code: Turn starting switch to ON position or start engine.
No.
Cause
Defective 5V sensor power
1
supply 1 system
Defective boom swing RH
PPC pressure sensor
2
(internal defect)
PC88MR-10
Boom Swing RH PPC Pressure Sensor Abnormality
Failure
(Pump controller system)
Procedure, measuring location, criteria and remarks
If failure code [DA25KP] is also displayed, perform troubleshooting for it
first.
1. Turn starting switch to OFF position.
2. Disconnect connector P07 and connect T-adapters to female side.
3. Turn starting switch to ON position.
a If power supply voltage is abnormal, proceed to check on cause 3.
Voltage
Between P07 (female) (3) and (1)
1. Turn starting switch to OFF position.
2. Insert T-adapters into connector P07.
3. Turn starting switch to ON position.
Voltage
Between P07 (2) and (1)
a If power supply voltage is normal and sensor output voltage is
abnormal, it is difficult to judge whether cause of failure is defective
sensor, ground fault or hot short circuit in wiring harness. Check as
below.
1. Turn starting switch to OFF position.
2. Replace connector P07 with connector of other PPC pressure
sensor.
3. Turn starting switch to ON position and display "Abnormality Record"
screen of electrical system on machine monitor.
4. If E mark is not displayed again for this failure code, boom swing RH
PPC pressure sensor is defective.
a After finishing test, restore connectors.
40 Troubleshooting
Troubleshooting by failure code (Display of code)
}.
2
Power
4.5 to 5.5
supply
V
Sensor
0.5 to 4.5
output
V
40-323