Failure code [DHSCMA] Arm OUT PPC Press Sens Def Function

DHSCMA-400-A-Z0-A)
Action level
Failure code
L01
DHSCMA
Detail of
Signal voltage of arm OUT PPC pressure sensor circuit is below 0.3 V or above 4.5 V.
failure
Sets arm OUT PPC pressure to 0 MPa {0 kg/cm
Action of
If cause of failure disappears, machine becomes normal by itself.
controller
Automatic deceleration does not cancel.
Problem on
Controllability of arm OUT deteriorates.
machine
a If 5 V circuit (3) and ground circuit (1) of pressure sensor are connected inversely,
pressure sensor will be broken. Accordingly, take extreme care when checking.
As T-adapter for pump controller connector is "socket-type box", operating voltage cannot
Related
be measured at pump controller connector.
information
Arm OUT PPC pressure can be checked with monitoring function.
(Code: 07600 Arm OUT PPC pressure)
Method of reproducing failure code: Turn starting switch to ON position or start engine.
No.
Cause
Defective 5V sensor power
1
supply 1 system
Defective Arm OUT PPC
pressure sensor (internal
2
defect)
PC88MR-10
Arm OUT PPC Pressure Sensor Defective Function
Failure
(Pump controller system)
Procedure, measuring location, criteria and remarks
If failure code [DA25KP] is also displayed, perform troubleshooting for it
first.
1. Turn starting switch to OFF position.
2. Disconnect connector P02 and connect T-adapters to female side.
3. Turn starting switch to ON position.
a If power supply voltage is abnormal, proceed to check on cause 3.
Voltage
Between P02 (female) (3) and (1)
1. Turn starting switch to OFF position.
2. Insert T-adapters into connector P02.
3. Turn starting switch to ON position.
Voltage
Between P02 (2) and (1)
a If power supply voltage is normal and sensor output voltage is
abnormal, it is difficult to judge whether cause of failure is defective
sensor, ground fault or hot short circuit in wiring harness. Check as
below.
1. Turn starting switch to OFF position.
2. Replace connector P02 with connector of other PPC pressure
sensor.
3. Turn starting switch to ON position and display "Abnormality Record"
screen of electrical system on machine monitor.
4. If E mark is not displayed again for this failure code, Arm OUT PPC
pressure sensor is defective.
a After finishing test, restore connectors.
40 Troubleshooting
Troubleshooting by failure code (Display of code)
2
}.
(PC88MR-
Power
4.5 to 5.5
supply
V
Sensor
0.5 to 4.5
output
V
40-317