8.3

Remote setting function

Even if the operation panel is located away from the enclosure, contact signals can be used to perform continuous variable-
speed operation, without using analog signals.
Pr.
Name
59
Remote function
F101
selection
 Remote setting function
• When Pr.59 ≠ "0" (remote setting enabled), the functions of the signals are as shown in the following table.
Signal name
STF/STR
RH
RM
RL
Terminal 2 (analog signal)
Inverter
Forward
rotation
STF
Acceleration
RH
Deceleration
RM
10
Clear
RL
2
SD
5
Connection
diagram for remote setting
 Main speed
• The main speed used in the remote setting corresponds with each of the following operation modes.
PU operation mode / NET operation mode
External operation mode / PU/External combined operation mode 2 (Pr.79 = "4")
PU/External combined operation mode 1 (Pr.79 = "3")
Initial
Setting
RH, RM, RL signal
value
range
0
Multi-speed setting
1
Remote setting
2
Remote setting
3
Remote setting
0
11
Remote setting
12
Remote setting
13
Remote setting
Function
Forward/Reverse
Acceleration
Deceleration
Clear
Main speed
Set frequency
Increased
(Hz)
according to the
Pr.44 setting
Terminal 2
(main speed)
RH (Acceleration)
RM (Deceleration)
RL (Clear)
STF (Forward)
Operation mode
Description
Frequency setting
function
storage
Enabled
Disabled
Disabled
(Turning OFF the STF/STR
signal clears the remotely-
set frequency.)
Enabled
Disabled
Disabled
(Turning OFF the STF/STR
signal clears the remotely-
set frequency.)
Description
The inverter accelerates the motor in the forward or reverse direction up to
the main speed or to the frequency stored by the remote setting function.
The set frequency increases according to the Pr.44 setting.
The set frequency decreases according to the Pr.45 setting.
The set frequency is cleared and the main speed is applied.
The setting of the main speed is used as a base. The main speed is
increased by the RH signal and decreased by the RM signal.
Decreased according to
the Pr.45 setting
ON
ON
ON
Digital setting
Analog input
Analog input via terminal 4 (AU signal ON)
8. (F) Settings for Acceleration/Deceleration
Deceleration to the
main speed or lower
Not available
Available
Cleared by RL
Time