• When Pr.992 = "100", the set frequency is displayed during stop, and output frequency is displayed during running.
Pr.992 setting
Status
0
During running/stop
During stop
100
During running
*1
Displays the frequency that is output when the start command is ON. The value considers the maximum/minimum frequency and frequency
jumps. It is different from the frequency setting displayed when Pr.992 = "5".
 Monitoring I/O terminals on the operation panel (Pr.52, Pr.774 to Pr.776,
Pr.992)
• When Pr.52 (Pr.774 to Pr.776, Pr.992) = "55 to 57", the I/O terminal state can be monitored on the operation panel.
• When a terminal is ON, the corresponding LED segment is ON. The center LED segments are always ON.
Pr.52, Pr.774 to Pr.776,
Pr.992 setting
55
I/O terminal status
*1
Option input terminal status
56
*1
Option output terminal status
57
*1
The setting value "56 or 57" can be set even if the option is not installed. All are OFF when the option is not connected.
• On the I/O terminal monitor, the upper LEDs indicate the input terminal status, and the lower LEDs indicate the output
terminal status.
I-2
I-3
I-5
I-6
I-8
I-1
I-4
I-7
O-1
O-4
O-7
O-2
O-5
O-8
O-3
O-6
O-9
Input terminal
Symbol
FR-E800
I-1
RL
I-2
RM
I-3
RH
I-4
I-5
I-6
I-7
MRS
I-8
RES
I-9
STF
DI0
I-10
STR
DI1
I-11
I-12
• The decimal point of the last digit on the LED is lit for the input option terminal monitor.
X1
X2
X4
X5
X7
X0
X3
X6
X10
X13
DY
X11
X14
X12
X15
Monitor displayed by the setting dial push
Set frequency
*1
Set frequency
Output frequency
Monitor item
Displays the I/O terminal ON/OFF state of the inverter.
Displays input terminal ON/OFF state of the digital input option (FR-A8AX)
Displays output terminal ON/OFF state of the digital output option (FR-A8AY) or
the relay output option (FR-A8AR).
Segments corresponding
I-9
I-11
I-12
to input terminals
I-10
The center LED segments are
always ON.
O-10
O-11
O-12
Segments corresponding
to output terminals
FR-E800-E
FR-E800-SCE
X8
X9
The center LED segments are always ON.
Decimal point LED of the last digit LED is always ON
Monitor description
- Display example -
When signals STF,
RH and RUN are on
Output terminal
Symbol
FR-E800
O-1
A,B,C
O-2
O-3
RUN
O-4
O-5
O-6
O-7
FU
O-8
SO
O-9
O-10
O-11
O-12
11.(M) Item and Output Signal for Monitoring
11.2 Monitor item selection on operation panel or via communication
FR-E800-E
FR-E800-SCE
A,B,C
A,B,C
SO
11
12
13
14
15
16
17
18
19
20
241

Advertisement

Table of Contents
loading

Table of Contents