Mitsubishi Electric 800 Series Instruction Manual page 308

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Function
Electronic thermal O/L relay
Applied motor
Control method selection
Motor capacity
Number of motor poles
Motor excitation current
Rated motor voltage
Rated motor frequency
Motor constant (R1)
Motor constant (R2)
Motor constant (L1)/d-axis inductance (Ld)
Motor constant (L2)/q-axis inductance (Lq)
Motor constant (X)
Auto tuning setting/status
Frequency search gain
Online auto tuning selection
Induced voltage constant (phi f)
Motor Ld decay ratio
Motor Lq decay ratio
Starting resistance tuning compensation
coefficient 1
Starting resistance tuning compensation
coefficient
Starting magnetic pole position detection pulse
width
Maximum motor frequency
Motor inertia (integer)
Motor inertia (exponent)
Motor protection current level
Torque current/Rated PM motor current
NOTE
• The RT signal is the Second function selection signal. The RT signal also enables other second functions. (Refer to
• For the RT signal, set "3" in any parameter from Pr.178 to Pr.189 (Input terminal function selection) to assign the function.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other functions.
Set parameters after confirming the function of each terminal.
 Automatic change of torque boost for the SF-PR motor (200/400 V class)
• When the SF-PR motor is selected (Pr.71 = "70 or 73"), the Pr.0 Torque boost setting is automatically changed to enable
output of the 6 Hz 150% torque under V/F control by setting Pr.81 Number of motor poles according to the number of
the SF-PR motor poles.
NOTE
• When selecting the automatic change of torque boost for the SF-PR motor, set Pr.14 Load pattern selection = "0 (initial
value)".
• When the Pr.0 setting is changed from its initial value, the automatic change is not performed.
 Automatic change of Pr.0 Torque boost and Pr.12 DC injection brake
operation voltage (200/400 V class)
• When initial values are set in Pr.0 and Pr.12, the Pr.0 and Pr.12 settings are automatically changed to the values in the
following table by changing the Pr.71 setting.
RT signal ON (second motor)
Pr.51
Pr.450
Pr.451
Pr.453
Pr.454
Pr.455
Pr.456
Pr.457
Pr.458
Pr.459
Pr.460
Pr.461
Pr.462
Pr.463
Pr.560
Pr.574
Pr.738
Pr.739
Pr.740
Pr.741
Pr.737
Pr.742
Pr.743
Pr.744
Pr.745
Pr.746
Pr.860
RT signal OFF (first motor)
Pr.9
Pr.71
Pr.800
Pr.80
Pr.81
Pr.82
Pr.83
Pr.84
Pr.90
Pr.91
Pr.92
Pr.93
Pr.94
Pr.96
Pr.298
Pr.95
Pr.706
Pr.711
Pr.712
Pr.717
Pr.720
Pr.721
Pr.702
Pr.707
Pr.724
Pr.725
Pr.859
13.(C) Motor Constant Parameters
13.1 Applied motor
11
12
13
14
15
16
17
18
19
20
page
298.)
307