5. OTHER FUNCTION
In this machine, the following functions can be set with OSD
5-1. MODEL NAME SETTING FUNCTION
5-2. SERIAL NUMBER SETTING FUNCTION
5-3. USAGE TIME SETTING FUNCTION
5-4. SYSTEM LOG AND TEMPERATURE LOG INITIALIZATION
5-5. SYSTEM LOG AND TEMPERATURE LOG PRESERVATION TO USB MEMORY
5-6. USER SETTING VALUE PRESERVATION TO USB MEMORY
5 – 1. MODEL NAME SETTING FUNCTION
1) Display SERVICE MENU 3.
2) Select "MODEL NAME SETTING" by using [VOL+ ()], [VOL-
()] buttons, and press [ENTER] button.
The screen of MODEL NAME SETTING is displayed.
3) Move the cursor to [SET] by using [VOL+ ()], [VOL- ()]
buttons, and then move the cursor to the edit line by using
[BRIGHT- ()], [BRIGHT+ ()] buttons.
<CAUTION>
*During the change procedure, do not close the window by
pressing [INPUT/RETURN] button. If the window is forcefully
closed halfway through the procedure due to power shut-off or
signal change etc., the figures being changed won't be written.
4) When the change has been completed, put the cursor on "Edit
line" and press [ENTER] button. The changed figures are
written, and then the screen returns to SERVICE MENU 3.
If "RETURN" is pushed, the changed figures won't be written.
<MEMO>
*The tailing blank columns are trimmed when the figures are
written.
Meanwhile, the blank columns among the figures are written as
spaces.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 7
Model name
String you want to edit
5 – 2. SERIAL NUMBER SETTING FUNCTION
1) Display SERVICE MENU 3.
2) Select "S/N SETTING" by using [VOL+ ()], [VOL- ()]
buttons, and press [ENTER] button.
The screen of S/N SETTING is displayed.
S/N SETTING
SERVICE1
SERVICE2
S/N : 8A012345K
SERVICE3
OK
3) By using [BRIGHT- ()], [BRIGHT+ ()] buttons, move the
cursor to the column which you want to change, and then
change the figure by [VOL+ ()], [VOL- ()] buttons.
<MEMO>
*The usable characters are 0 to 9, A to Z (capital letters only),
space, - (hyphen), _(underbar) and .(comma).
<CAUTION>
*During the change procedure, do not close the window by
pressing [INPUT/RETURN] button.
If the window is forcefully closed halfway through the procedure
due to power shut-off or signal change etc., the figures being
changed won't be written.
4) When the change has been completed, press [ENTER] button.
The changed figures are written, and then the screen returns to
SERVICE MENU 3.
If "RETURN" is pushed, the changed figures won't be written.
<MEMO>
The tailing blank columns are trimmed when the figures are
written. Meanwhile, the blank columns among the figures are
written as spaces.
Current S/N
8 A
0 1 2 3 4 5
K
Edit line
[MENU]
BACK
[RETURN]