3)Press "ESC" key to end the tool.
4)Confirm the result of Pen Touch Accuracy Check
Click " Yes" button, if passing the test of X and Y-axis gap.
-> go to Drawing Check
Click "No" button, if failing the test of X or Y-axis gap.
-> go to Calibration Touch Position
Click "Cancel" button, to quit TC Adjustment.
NG
OK
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 35