5 – 3. USAGE TIME SETTING FUNCTION
1) Display SERVICE MENU 3.
2)Select "S/N SETTING" by using [VOL+ ()], [VOL- ()]
buttons, and press [ENTER] button.
The screen of S/N SETTING is displayed.
USAGE TIME SETTING
SERVICE1
SERVICE2
USAGE TIME : 123456 H
SERVICE3
OK
3) Change the figure by [VOL+ ()], [VOL- ()] buttons.
<MEMO>
*The setting range is 0 to 200000. (Default: 0)
4) When the change has been completed, press [ENTER] button.
The changed figures are written, and then the screen returns to
SERVICE MENU 3.
If "RETURN" is pushed, the changed figures won't be written.
PN-K321/K322B SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4 - 8
Current
USAGE TIME
123456
Edit line
[ENTER]
[MENU]
BACK
[RETURN]
5 – 4. SYSTEM LOG AND TEMPERATURE
LOG INITIALIZATION
■SYSTEM LOG
1 ) Display SERVICE MENU 3.
2 ) Select "SYSTEM LOG INITIALIZE" by using [VOL+ ()],
[VOL- ()] buttons, and press [ENTER] button.
The screen of SYSTEM LOG INITIALIZE is displayed.
3 ) Press [BRIGHT+ ()] button to select "ON", and press
[ENTER] button. The initializing process starts.
If you select "OFF" and press [ENTER] or [RETURN] button,
the screen goes back to the previous one.
The cursor is placed on "SYSTEM LOG INITIALIZE".
4 ) During the initializing process, the message of [INITIALIZING]
Is displayed.
When the initialization has been completed, the SERVICE
MENU window is displayed.
■TEMPERATURE LOG
1) Display SERVICE MENU 3.
2) Select "TIEM LOG INITIALIZE" by using [VOL+ ()], [VOL-
()] buttons, and press [ENTER] button. The screen of TIEM
LOG INITIALIZE is displayed.
3) Press [BRIGHT+ ()] button to select "ON", and press
[ENTER] button.The initializing process starts. If you select
"OFF" and press [ENTER] or [RETURN] button, the screen
goes back to the previous one. The cursor is placed on "TEMP
LOG INITIALIZE".