SECS Item
Window
[GEM Function]  [Common Alarm]  [SECS Item]
Displayed items
Item
Item
Data Type
Data Counts
Variable Length
Exclusion
Window
[GEM Function]  [Common Spool]  [Exclusion]
Displayed items
Item
Scenario
Enable
Processing Notification
Data Lock
ABORT
Description
Configure the data type and data count of items used by the message.
Select the data type of the item.
Configure the data count of the item.
Select this checkbox to configure the data count to a variable length.
Description
Select the transaction in the GEM spool scenario.
The following transactions can be selected.
• S2F43: Reset Spooling Streams and Functions
• S6F23: Spooled data request
Select this checkbox to enable automated response of the selected transaction.
Configure the relay for the SECS/GEM communication software to notify the programmable controller
CPU that the selected transaction is being executed.
Configure the relay to deny the above-mentioned transaction request because of equipment
processing, errors, etc.
When this relay is ON, secondary messages are not returned when a message related to the selected
transaction is received from the host.
When the "ABORT" checkbox is selected, an SxF0 secondary message is sent.