Mitsubishi Electric MELSEC iQ-R Series User Manual page 160

C controller/c intelligent function module secs/gem communication software pre-installed model
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

User Log Setting
Series
MELSEC-Q series
MELSEC iQ-R series
The user log settings allow string data stored in the specified register to be output as a log when the specified trigger switching
ON is detected and browse data using the "Log View" screen in the setting tool.
Window
[Log]  [Log Output Setting]  [User Log Setting] tab
Displayed items
Item
User Log Setting
7 BASIC FUNCTIONS
158
7.17 Log Output
SECS/GEM communication software
Non-GEM version
User Log Output Request
User Log Start Register
Register Counts
GEM version
Description
Select this checkbox to enable the user log setting.
Configure the user log output trigger.
If the trigger is turned ON by the programmable controller CPU, and the log output ends, it is
switched OFF by the SECS/GEM communication software.
Configure the start register where the data (ASCII strings) to be output to a log are to be
stored.
Configure the number of registers (number of words) to be used for data storage counting.
When the data does not satisfy this size, fill the terminating byte with NULL characters (0x00).
GEM advanced version