CA-SECS device assignment (I/O assignment)

Series
MELSEC-Q series
MELSEC iQ-R series
Devices of a programmable controller CPU, a SECS/GEM communication software pre-installed model module, and an I/O
module need to be configured in "CA-SECS Device Assignment(I/O assignment)" to use them in the SECS/GEM
communication software.
Window
[Setting]  [Device Assign Setting]
■MELSEC-Q series
■MELSEC iQ-R series
Displayed items
■MELSEC-Q series
Item
Channel
Network number
STA#
Device
Device Start
Points (Words)
■MELSEC iQ-R series
Item
CPU No.
Device
Device Start
Points (Words)
7 BASIC FUNCTIONS
82
7.6 Device Assignment
SECS/GEM communication software
Non-GEM version
Description
Select "Q-bus".
Do not enter data.
Configure the CPU number.
Use the device function of the Setting/monitoring tools for the C Controller module to configure the station number to
"255" (own station) to access the station device ("M" or "D").
Select a device.
Configure the start of device numbers.
Configure the number of device points to be used in word units.
There are restrictions for setting the number of points (the number of words).
For details on the restrictions, refer to the following:
Page 83 Restrictions for setting the number of points (the number of words)
Description
Configure the CPU number of the control CPU.
Select a device.
Configure the start of device numbers.
Configure the number of device points to be used in word units.
There are restrictions for setting the number of points (the number of words).
For details on the restrictions, refer to the following:
Page 83 Restrictions for setting the number of points (the number of words)