NEC Express5800 User Manual page 35

Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

Virtual LCD indications when STATUS lamp is flashing in red
On-screen message
Proc 1 IERR
Proc 2 IERR
Proc1Didn'tStart
Proc2Didn'tStart
WDT Timeout
WDT Power Down
SMI Timeout
ErrPause in POST
DUMP Request !
Memory U-Err XX
Proc Missing
Proc1 Config Err
Proc2 Config Err
MEZZ1 PowerFault
MEZZ2 PowerFault
Proc1ThermalTrip
Proc2ThermalTrip
AmbientTempAlm09
AmbientTempAlm02
Description
An error was detected in CPU#1.
An error was detected in CPU#2.
CPU#1 failed to start POST.
CPU#2 failed to start POST.
Watchdog timer timeout error
occurred.
Forcedly powered off due to
watchdog timer timeout error.
A timeout error occurred while
the system management
interrupt process is in progress.
The system is waiting for key
entry due to serious POST error.
Under memory dump request
An uncorrectable memory error
was detected. XX denotes the
DIMM slot number with 1-origin
that contains the failed DIMM.
No CPU is installed in slot
CPU#1.
The CPU installed in the CPU#1
slot is unsupported or its
combination is illegal.
The CPU installed in the CPU#2
slot is unsupported or its
combination is illegal.
An error was detected in power
circuit of mezzanine card
installed in Type I slot.
An error was detected in power
circuit of mezzanine card
installed in Type II slot.
Forced power-off occurred due to
a thermal error in CPU#1.
Forced power-off occurred due to
a thermal error in CPU#2.
A high temperature error was
detected in chassis.
A low temperature error was
detected in chassis.
General Description 2-11
Action
1. Turn of the power once and then
on again.
2. If a certain error message
appears on POST screen, check
the message.
3. If no error message appears,
check the system by using the
Off-line Maintenance Utility.
Check the error message on POST
screen.
Wait until dump collection
completes.
1. Check installation status DIMM.
2. Replace the DIMM.
Check installation status of CPU.
Check if the installed CPU is
supported by the system.
Check combination of performances
such as frequency between CPU#1
and CPU#2.
1. Check installation status of
mezzanine card.
2. Replace the mezzanine card.
Check if fans in Blade Enclosure
work normally.
Check the heat sink of the CPU
blade.
Refer to the User's Guide of the
Blade Enclosure to make sure that
the sufficient number of fans are
installed in correct locations.
Check if the fans and CPU blades
are installed in correct locations.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.
Check if the ambient temperature of
installation location satisfies the
operation guarantee condition.

Advertisement

Table of Contents
loading

Table of Contents