Installation
6. Checking after installation
After installation, check the following items, and perform test run. Then, be sure to put your signature and explain
to the customer that installation has completed.
Fixing bolts
Cause of vibration and abnormal sound
2 fi xing bolts for transfer are removed, and
covers are attached instead. (P.49)
Fixing bolts (2)
Do not remove the fastener of the drain hose.
Doing so will prevent the drum from being fi lled
with water, and washing is impossible.
Adjustable feet
The 2 adjustable feet are stable and securely
tightened. (P.53)
The 4 feet are properly attached and not
deformed.
Installation place
The main unit is installed on the fi rm location
and is not rattling. (P.53)
Leveller
The bubble is inside the circle of the leveller,
showing the appliance is horizontally installed.
(P.53)
54
(continued)
Installer's signature
Power plug
The socket is singly connected to the power
source.
(Rated at 10 A and AC 220 to 240 V)
Leveller
Power plug
Water supply
hose
Drain hose
Adjustable
feet (2)
Water supply hose
The water supply hose is properly connected,
and free from leaks. (P. 52)
Drain hose
The drain hose is properly connected, and
water drains normally. (P. 52)
The drain outlet is not clogged with foreign
objects, etc.
Perform Test Run!
 With nothing inside the drum, check if "Water leak, abnormal sound and vibration are not
present." and "Water is drained properly."
Test run method
Ensure that the fi xing bolts for transfer have
been removed before test run!
(1) Fully open the water faucet, and close the
door.
(2) While pressing and holding
, press
+
quickly. Then while
is being displayed, press
within 3
seconds.
(3) While
is being displayed, press
.
(4) Start operation. (Automatically fi nishes in
approx. 3 minutes.)
(Note)
You cannot operate with rubber gloves on.
Attention
Do not wipe the main unit with gritty cleanser, thinner, benzine, alcohol, kerosene, etc.
Note
Before shipment, a water injection inspection is performed, which may cause the window to become foggy, or
water droplets to remain inside the drum. This is not a malfunction.
(Otherwise, water leak may occur.)
Check points
No abnormal sound or vibration?
→Check if the appliance is installed horizontally.
No water leak?
→Connect the hose correctly.
The following error messages appear when
abnormality is detected.
*1
U11
• The drain outlet is clogged.
*1
U14
• The water supply hose is not
connected or the water faucet is not
turned on.
*1 After the error status is released, by pressing "Start", the
test run will resume.