NEC Express5800 Series Maintenance Manual page 119

Express server
Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C10B
BMC operational code
corrupted.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC
FRU corrupted.
C10E
BMC SDR Repository
empty.
C10F
IPMB signal lines do not
respond.
BMC FRU device failure. An error was detected in FRU that
C110
C111
BMC SDR Repository
failure.
BMC SEL device failure. Device failure was detected in BMC
C112
C113
BMC RAM test error.
C114
BMC Fatal hardware
error.
C115
Management controller
not responding
C116
Private I2C bus not
responding.
BMC internal exception BMC internal error was detected.
C117
BMC A/D timeout error. BMC A/D timeout error was
C118
SDR repository corrupt. BMC error or illegal SDR data was
C119
C11A
SEL corrupt.
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition
is invalid.
C11D
BMC is in Forced Boot
Mode.
C200
The error occurred
during memory
configuration check.
C201
Memory Configuration
change is detected.
C202
The error occurred
during CPU
configuration check.
Cause
Failed to start BMC firmware.
An illegality was detected in FRU
containing the device information.
An error was detected on BMC SDR.
Failure of Satellite Management
Controller was detected.
contains device information.
Failure was detected in SROM that
stores the SDR.
SEL.
An error was detected in BMC RAM.
A hardware error was detected in
BMC.
Management controller does not
respond.
Private I2C bus does not respond.
detected.
detected.
BMC error or illegal system event log
data was detected.
BMC Mezzanine card is not installed. Contact your sales representative.
A format error was detected in BMC
Mezzanine card.
Detected that BMC is in Forced Boot
Mode.
Memory configuration could not be
obtained.
The memory configuration has
changed since the previous startup.
The CPU information could not be
obtained.
Express5800/E120e-M Maintenance Guide
1. POST Error Message
Solution
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Update the BMC firmware.
If the same error is detected repeatedly,
contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same
error is detected repeatedly, contact your
sales representative.
Check the jumper switch setting on
motherboard. Unplug the power cord, wait
for at least 30 seconds, then restart the
server. If the same error is detected
repeatedly, contact your sales
representative.
Contact your sales representative.
When Check previous system Config is
enabled in Server of the setup, this message
appears if the configuration was changed
since the previous startup. If this message
appears even when no configuration change
has been made, contact your service
representative.
Contact your service representative.