Built-in Positioning Functions
8.2
Drive to Increment - DRVI Instruction
8.2.1

Instruction Format

1. Instruction Format
FNC 158
D
DRVI
DRIVE TO
INCREMENT
Command
input
FNC158
DRVI
2. Data setting
Operand type
S
1
S
2
D
1
D
2
*1.
Setting range : -32,768 to +32,767 (excluding 0) for 16-bit operation
*2.
Setting range : 10 to 32,767 Hz for 16-bit operation
3. Devices
Operand
type
X
Y
S
1
S
2
1
D
1
2
D
2
1 : Specify Y000, Y001, or Y002
*5
Y003
from a high-speed output special adapter
*3.
Y002 is not available in FX
*4.
High-speed output special adapters can be connected only to the FX
*5.
To use Y002 and Y003 with a high-speed output special adapter, connect a second high-speed output
special adapter.
Note:
• To use an FX
special adapter.
• Differential line drive type outputs will be used for the outputs of the high-speed output special adapter.
B - 122
PLC User's Manual - Positioning Control Edition
16-bit
Instruction
instruction
symbol
DRVI
9 steps
-
S
S
D
2
1
1
Specifies the number of output pulses (relative address).
Specifies the output pulse frequency.
Specifies the pulse output number.
Specifies the rotation direction signal output destination device number.
: -999,999 to +999,999 (excluding 0) for 32-bit operation
For 32-bit operation, however, the setting range is as shown in the following table.
FX
PLC
3U
FX
/FX
/FX
/FX
3S
3G
3GC
Bit device
System user
Digit designation
M T C S D.b KnX KnY KnM KnS T C D
3
*3
transistor output from the main unit, or specify Y000, Y001, Y002
PLC (14-point and 24-point type) and FX
3G
PLC of relay output type or triac output type, be sure to connect a high-speed output
3U
8 1-Speed Positioning - DRVI/DRVA Instruction
Execution condition
instruction
Continuous
execution
type
D
2
Description
*2
Pulse output destination
High-speed output special adapter 10 to 200,000(Hz)
/FX
PLC Main unit (transistor output)
3U
3UC
Word device
System user
R U\G V Z Modify K
4
  
4
  
*4
.
8.2 Drive to Increment - DRVI Instruction
32-bit
Instruction
Execution condition
symbol
DDRVI
17 steps
-
*1
Spe-
Con-
cial
Index
num-
stant
unit
H
5
 
 
5
 
 
/FX
PLC.
3S
3GC
PLC.
3U
Continuous
execution
type
Data type
BIN16/32-bit
Bit
Setting range
10 to 100,000(Hz)
Others
Real
Char-
acter
Pointer
ber
string
E
""
P
*5