Example program:
The following program shows that the interrupt input for Y000 is set using the user interrupt input
command (M8460).
M8002
Initial pulse
Command
input
M8348
Positioning
being
performed
(Y000)
M100
Interruption
positioning being
performed
M100
Interruption
positioning being
performed
M100
Interruption
positioning being
performed
Interruption
M103
pointer I0
Interruption
condition
After specifying a user interrupt input command for the interrupt input signal, if the specified device is
turned on, the number of pulses specified by
Before activating the Interrupt Positioning instruction again, be sure to turn off the user interrupt input
command.
PLC User's Manual - Positioning Control Edition
M101
M102
Normal
Abnormal
end of
end of
positioning
positioning
M8029
"Instruction execution complete" flag
M8329
"Instruction execution abnormal end" flag
9 One-speed Interrupt constant quantity feed - DVIT Instruction
FNC 12
MOV
FNC151
S
S
1
2
DVIT
will be output and then the operation will be stopped.
S
1
9.3 Function and Operation
FNC 04
EI
Specifies the
interrupt input for
HFFF8
D8336
Y000 in the user
interrupt input
specification register.
Interrupt input
SET
M8336
specification
function enable.
Executes DVIT
Y000
D
2
instruction
Interruption
positioning is
M100
being
performed.
M101
"Positioning
operation
normal end"
flag
M102
"Positioning
operation
abnormal end"
flag
Interruption
SET
M103
condition
RST
M103
FNC 06
FEND
Interrupt input
signal: ON
SET
M8460
Interrupt input
signal: OFF
RST
M8460
RST
M103
FNC 03
IRET
END