Example Connection
*3.
To ensure safety, use the forward rotation limit switch and the reverse rotation limit switch on both sides: the PLC side and
the servo amplifier side.
Note that the limit switches on the PLC side should be activated slightly earlier than the limit switches on the servo
amplifier side.
Reverse rotation limit 2
(Servo amplifier side)
Servo motor
*4.
For details on the internal power supply of MR-J2 (S) servo amplifier, refer to the following manual.
Apx. - 32
PLC User's Manual - Positioning Control Edition
Reverse rotation limit 1
(Programmable
controller side)
LSR
Reverse rotation
Appendix 4. MELSERVO-J2 (-Super) Series
Appendix 4-1 Main Unit (Transistor Output)
Forward rotation limit 1
Forward rotation limit 2
(Programmable
(Servo amplifier side)
controller side)
LSF
Forward rotation
For details, refer to the servo amplifier manual.