Mitsubishi Electric Lossnay LGH-RX5-E Series Manual page 8

Advertisement

4.3
System Selection
Interlocked with City Multi
Lossnay operation when indoor unit is stopped
Lossnay stopping when indoor unit is operating
Switching Lossnay fan speed
When interlocked with indoor unit for compatibility with both R22, R407C and R410A
When interlocked with indoor unit for other than the above
Ventilation mode
Filter maintenance indicator
Lossnay error indicator
Delayed operation
External control operating mode selection
Number of indoor units for interlocked group setting with one Lossnay unit
Number of Lossnay units for interlocked group setting with one indoor unit
* All Lossnay functions including Extra-Low fan speed can be controlled from PZ-60DR-E.
Interlocked with Mr. Slim
When using A-control remote controller
Lossnay operation when indoor unit is stopped
Lossnay stopping when indoor unit is operating
Lossnay fan speed switching
Other common items
Lossnay error indicator
Ventilation mode
Filter maintenance indicator
Delayed operation
External control operating mode selection
Number of indoor units for interlocked group setting with one Lossnay unit
Number of Lossnay units for interlocked group setting with one indoor unit
Independent Lossnay Unit ( Not interlocked with
City Multi or Mr. Slim systems. )
Start/Stop
Fan speed switching
Ventilation mode
Filter maintenance indicator
Lossnay error indicator
Delayed operation
External control operating mode selection
Number of Lossnay units
Number of remote controllers
* All Lossnay functions including Extra-Low fan speed can be controlled from PZ-60DR-E.
Interlocked with external device ( BMS )
Start/Stop
Fan speed switching
Ventilation mode switching
Filter maintenance indicator
Lossnay error indicator
Delayed operation
External control operating mode selection
● ●
*
: Available
× : Not Available
C-8
( Refer to page C-14 )
● ●
● ●
High/Low
Fixed to high
Fixed to automatic
● ●
● ●
● ●
×
16 units
One unit
( Refer to page C-13 )
● ●
×
High/Low
×
Fixed to automatic
×
● ●
×
One unit
One unit
( Refer to page C-11 )
● ●
High/Low/Extra Low
Heat ex. /
By-pass/ Auto
● ●
● ●
● ●
● ●
15 units
Two units
( Refer to page C-22 )
● ●
Fixed to high
Fixed to automatic
×
×
● ●
● ●
Incase of PZ-60DR-E
Air
Air
conditioner
conditioner
MA remote
M-NET transmission cable
controller
Incase of PZ-52SF-E
Air
Air
conditioner
conditioner
MA remote
M-NET transmission cable
controller
Mr.Slim ( A-control )
indoor unit
Lossnay unit
LGH-RX type
Remote controller
Slim-Lossnay connecting cable
( Enclosed accessory with Lossnay unit)
Lossnay unit
LGH-RX type
Lossnay remote controller
(PZ-60DR-E, PZ41SLB-E)
External signal source
for interlocking
to the Lossnay
Lossnay
PZ-60DR-E can be used
Lossnay
PZ-52SF-E can be used
Lossnay remote
controller
PZ-60DR-E,
PZ-41SLB-E
cannot be used.
External signal source
for interlocking
to the Lossnay
Lossnay unit
LGH-RX type