Antennas
6.2 SIMATIC RF615A
C C able designa-
t t ion
Antenna cable
(suitable for drag
chains)
Antenna cable
Antenna cable
1)
2)
6 6 .2.5

Antenna parameter assignment

Depending on the country or region in which the antenna is being operated, it is subject to
regional limitations with respect to the radiated power.
Limitations in the EU, EFTA, or Turkey
Note
L L imitation of the radiated power according to EN 302 208 V1.4.1 (ETSI)
RF600 systems that are put into operation in the EU, EFTA or Turkey must not exceed the
following radiated power with an RF615A antenna:
500 mW ERP (or 27 dBm ERP)
Converted into EIRP: 820 mW EIRP (or 29 dBm EIRP)
Make the following settings to ensure that the maximum permitted radiated power of the
antenna is not exceeded:
Antenna gain: -5 dBi
Radiated power:
Converted into EIRP:
Use of cable loss associated with the antenna cable.
236
A A rticle number
6GT2815-2BN15
6GT2815-0BN20
6GT2815-0BN40
Permissible minimum bending radius with one-time bending. 28 mm
With cables capable of being used in drag chains, 100,000 bending cycles at a bending radius of
100 mm and a bend of ± 180° or 3 million torsion cycles with a bend of ± 180° on a cable length of
1 m are permitted.
340 mW ERP (or 25.35 dBm ERP)
L L ength [m]
15
20
40
560 mW EIRP (or 27.5 dBm EIRP)
System Manual, 06/2019, J31069-D0171-U001-A22-7618
C C able loss [dB]
B B ending radius
[ [ mm]
1) 2)
4
45
4
77
5
77