System diagnostics
9.1 Diagnostics via the LED displays of the reader
9 9 .1.2

Diagnostics via LED operating display

The operating states of the reader are displayed by the "RUN/STOP", "ERROR",
"MAINTENANCE" and "PRESENCE" LEDs. The LEDs can adopt the colors green, red or
yellow and the statuses off , on
Table 9- 1
Display of operating statuses
R/S
ER
--
--
--
--
--
--
--
--
1)
Not present on the RF650R.
2)
Not present on the RF680R/RF685R.
--: Not relevant
472
1 1 )
2 2 )
MAINT
PRE
Meaning
The device is turned off.
The device is starting up.
--
--
The device is ready for operation. The connection to the application
(XML, OPC UA, controller) is not established.
There may be an error.
--
--
The device is ready for operation but there is an error.
--
--
The device is ready for operation. The connection to the application
(XML, OPC UA, controller) is established.
--
--
The device is working.
Flash test for reader identification.
--
--
There is an error. You will find more information on error messages in
the section "XML/PLC error messages (Page 473)".
--
--
The network load too high. The functioning of the device is being dis-
turbed due to receiving too many network packets.
--
The antenna is switched on. There is no transponder in the antenna
field.
--
There is at least one transponder in the antenna field.
--
One or more transponders have been detected as valid.
, flashing :
STEP 7, Ethernet/IP: The "writeconfig" command was received.
XML application: The "hostGreeting" command was received.
OPC UA: Connection to the client is established.
System Manual, 06/2019, J31069-D0171-U001-A22-7618