HP Brio 7100 User Manual page 78

For hp vectra pcs and hp kayak pc workstations
Hide thumbs Also See for Brio 7100:
Table of Contents

Advertisement

Appendix A The Error Codes
0601h – 0617h: Serial Port Error Codes
Code
0609h
FIFO trigger level test failed at port
XXXXh.
0610h
FIFO character timeout indication test
failed at port XXXXh.
0611h
FIFO data transfer test failed at port
XXXXh.
0612h
Baud rate speed test failed.
0613h
Infrared register test failed at port
XXXXh.
0614h
Infrared interrupt ID test failed at port
XXXXh.
0615h
Infrared internal loopback test failed at
port XXXXh.
0616h
Infrared line status test failed at port
XXXXh.
0617h
Infrared data transfer test failed at port
XXXXh.
66
Explanation
English
Details/Parts to Check
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.
If the test is running on a 16650 UART, check the
frequency selected in the test menu matches the
jumper settings on the card.
Re-run the diagnostics test.
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.
Serial port controller error.
Install new system board.

Hide quick links: