Code
0A10h
Random play test failed.
No data in Drive x.
0A11h
No audio tracks in the multisession CD in
drive x
0A12h
Number of audio tracks inadequate for
the test.
0C00h – 0C07h: IDE Tape Error Codes
Code
0C01h
No medium in tape drive n.
0C02h
Medium write protected.
0C03h
Rewind failed.
0C04h
Erase failed.
0C05h
Write failed.
0C06h
Read failed.
Explanation
Explanation
0C00h – 0C07h: IDE Tape Error Codes
Details/Parts to Check
CD-ROM error.
Insert an audio CD in the CD-ROM drive and re-run
the diagnostic test.
CD-ROM error.
Insert an audio CD in the CD-ROM drive and re-run
the diagnostic test.
CD-ROM error.
Insert another multisession CD in the CD-ROM drive
and re-run the diagnostic test.
Details/Parts to Check
Insert a tape cartridge in the tape drive and re-run
the test.
Tape's record switch is in write-protect position.
Move the switch to record position.
Change the tape in the tape drive and re-run the
diagnostics test.
Change the tape in the tape drive and re-run the
diagnostics test.
Re-run the diagnostics test.
Re-run the diagnostics test.