3-2-1 Preparation by users
⑧Optional Power Supply Unit
Optional Power Supply Unit (PSU) is a unit used in
combination with KD-CX series or KD-CX-NL series, and
not included in the product package (optional).
For details of the optional Power Supply Unit, refer to
Data sheet (TM-XH499), or Appendix E of this document.
Necessary quantity
L1(KD6R367CX / CS-NL)
L2 (KD6R587CX / CS-NL/ CXS),
/ L3 (KD6R807CX / CS-NL)
【Remarks】
Optional PSU can be used only for KD-CX series
or KD-CX-NL series.
TM-XH719C
3-2 Preparation
KDCX24VPW
: 1 unit
: 2 units
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
⑨ DC24V cable for Optional PSU
DEU-9S-F0R(JAE) for the housing on cable,
030-50634 (JAE) for the contact socket is recommended
Optional PSU has
DEU-9P-F0R(JAE) for the connector,
030-50635(JAE) for the contact pin
Pin assignment of Optional PSU connector is as shown below
KDCX Optional Power Supply Unit KDCX24VPW
CN91
Pin
Name
I/O
No
1
+24V power
2
3
4
NC
5
LED_CONT
6
7
GND
8
9
NC
By using 5
th
pin "LED_CONT" control signal port, the illumination ON/OFF
can be directly controlled. If the direct control of the illumination is not
necessary, connect 5
th
pin to GND with low impedance.
【Remarks】
When you use a cable in the field as the power cable, confirm the
connection and the cable length and standard carefully.
Cable resistance 600mΩ or less between the power supply and CIS is
recommended.
(Cable standard AWG22: approx. 10m, AWG20: approx. 15m, AWG18:
approx. 25m)
Remarks
I
VDD
-
OPEN: LED off
I
GND: LED on
I
GND
-
55