Setting⑤: Sync Signal Setting - Mitsubishi Electric KD Series User Manual

Contact image sensor (cis)
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

Address
Register name
6028 TriggerMode
7000 LinePeriodCounter
5-2-6 Sync Signal Setting
[Function]
Select a Sync Signal input source.
Select External Sync mode and provide sync signals to
CIS, when your object transport speed is changeable. (For
more details, please refer to Chapter 4-3.)
Select Internal Sync mode and control line frequency, when
your object transport speed is fixed. You can change line
frequency max. 1,872 usec/line.
TM-XH719C
5-2 Setting⑤: Sync signal setting
R/W
Val
Set Sync Signal input source
R/W
0 or 1
0: Internal Sync mode
1: External Sync mode
0
Set Line Frequency (Internal Sync mode)
R/W
To
65535
COPYRIGHT©2017-2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Result
Line Frequency �������� =
[Remark]
1) When using External Sync mode, provide sync
signals which have scanning frequency
corresponding to your transport speed of the
object you scan or CIS.
Initial
���������������� ���������� + 1
35
0
692
77

Advertisement

Table of Contents
loading

Table of Contents