5. Hardware Settings

5.1. Settings of the CC-Link Master Station

5.1.1. CR75n-D/CRnD-700 series

The details of the setting of the master station are shown in the following. For details, please refer to "the
cc-Link system master local unit
Figure 5.1-1 The outline of the CC-Link master-station unit (Q series)
As shown in Table 5-1, set up the rotary switch of the CC-Link master-station unit.
For details, please refer to "the cc-Link system master local unit user's manual (volume on details)."
Table 5.1-1 The setup of the CC-Link master-station unit (Q series)
Item
②Station
number
③Mode
Rotary
switch
Notice) When the mode of the master station is changed, change the parameter "CCSPD" of
the robot controller.
user's manual (volume on details)."
Details of setting
X10:Set the ten digit of a station number
X1:Set the ten digit of a station number
Set the mode
0:Transmission speed 156kbps
1:Transmission speed 625kbps
2:Transmission speed 2.5Mbps
3:Transmission speed 5Mbps
4:Transmission speed 10Mbps
14
LED
Rotary switch (station number)
Rotary switch (mode)
Terminal
At shipping
0
0
0
Example
of setting
0
0
4