Cr800-Dseries - Mitsubishi Electric MELFA CR800-D Series Instruction Manual

Hide thumbs Also See for MELFA CR800-D Series:
Table of Contents

Advertisement

5.1.2. CR800-D series
The details of the setting of the master station are shown in the following. For details, please refer to
"MELSEC iQ-R CC-Link System Master/Local Module User's Manual (Startup)".
Figure 5.1-2 The outline of the CC-Link master-station unit (iQ-R series)
As shown in Table 5-1, set up the rotary switch of the CC-Link master-station unit.
For details, please refer to "MELSEC iQ-R CC-Link System Master/Local Module User's Manual
(Startup)".
Table 5.1-2 The setup of the CC-Link master-station unit (iQ-R series)
Item
②Station
number
③Mode
Rotary
switch
Notice) When the mode of the master station is changed, change the parameter "CCSPD" of
the robot controller.
Details of setting
X10:Set the ten digit of a station number
X1:Set the ten digit of a station number
Set the mode
0:Transmission speed 156kbps
1:Transmission speed 625kbps
2:Transmission speed 2.5Mbps
3:Transmission speed 5Mbps
4:Transmission speed 10Mbps
15
LED
Dot matrix LED
Terminal block
Production information marking
At shipping
0
0
0
Example
of setting
0
0
4

Advertisement

Table of Contents
loading

Table of Contents