Mitsubishi Electric MELSEC-Q Series User Manual page 212

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

11 PROCESSING TIMES OF THE BASIC MODEL QCPU
11 - 4
3) As KN1 and KN2, use the values in the following table.
When the intelligent module is installed on the main base unit
CPU Type
Q00JCPU
Q00CPU
Q01CPU
When the intelligent module is installed on the expansion base unit
CPU Type
Q00JCPU
Q00CPU
Q01CPU
(Example)
When the number of automatic refresh points is 4 for the analog-digital
converter module (Q64AD) (when installed on the main base unit of
Q01CPU)
0.249 (ms) = 0.085 + 0.041
(5) Execution times of various functions processed at END
(a) Calendar update processing time
1) Time to write the clock data stored in SD210 to SD213 to the clock
element at END processing when a clock data set request is given
(SM210 turns from OFF to ON).
2) Time to read the clock data to SD210 to SD213 at END processing
when a clock data read request is given (SM213 turns ON).
CPU Type
Q00JCPU
Q00CPU
Q01CPU
(b) Error cancel processing
Time to cancel the continuation error stored in SD50 on the leading edge of
SM50 (error cancel) (when it turns from OFF to ON).
CPU Type
Q00JCPU
Q00CPU
Q01CPU
-3
KN1 ( 10
ms)
111
91
85
-3
KN1 ( 10
ms)
113
92
86
4
END Processing Time (ms)
At clock data set request
0.12
0.11
0.10
Common Processing Time (ms)
Annunciator
0.17
0.14
0.13
MELSEC-Q
-3
KN2 ( 10
ms)
55
46
41
-3
KN2 ( 10
ms)
56
48
43
At clock data read request
0.04
0.03
0.02
Other error
0.10
0.09
0.08
11 - 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qcpuMelsec q00jcpuMelsec q00cpuMelsec q01cpu

Table of Contents