Setting items
4
Settings
CH settings of CBP REPRICA (Function ID: 4F0B01)
Setting item
CH1-POS
CH use_CH1
CH name_CH1
Bay
BayDevice_CH1
Device
Coupler No_CH1
Zone1_CH1
Zone2_CH1
Protection
Zone3_CH1
zone
ZoneR1_CH1
Zone-NoDIF_CH1
CH1
CB_CH1
DS11_CH1
DS12_CH1
DS13_CH1
Bay
DS21_CH1
structure
Line1_CH1
Line2_CH1
Line3_CH1
CT-Pos_CH1
ZACbyCB_CH1
CH use_CH2
CH name_CH2
Bay
BayDevice_CH2
Device
Coupler No_CH2
Zone1_CH2
Zone2_CH2
Protection
Zone3_CH2
zone
ZoneR1_CH2
CH2
Zone-NoDIF_CH2
CB_CH2
DS11_CH2
DS12_CH2
Bay
structure
DS13_CH2
DS21_CH2
Line1_CH2
Range
BIO#1 / BIO#2 / BIO#3 /
BIO#4 / BIO#5 / BIO#6 /
BIO#7 / BIO#8
Off / On
[Preferred name]
Non / Feeder / Coupler /
EndSection
1 – 8
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non /Exist
Non /Exist
Non /Exist
Pos1 / Pos2
Off / On
Off / On
[Preferred name]
Non / Feeder / Coupler /
EndSection
1 – 8
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / ZoneA / ZoneB / ZoneC /
ZoneD / ZoneE / ZoneF
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non / NO / NC / Both /
DirConn
Non /Exist
- 26 -
Contents
Units
CH1's BIO starting position
–
CH use definition
–
CH name definition
–
Bay device selection
–
Coupler No. definition
–
First defined zone for forward protection
–
Second
defined
zone
–
protection
Third
defined
zone
–
protection
Defined zone for reverse protection
–
CH's current is unused in the DIF zone
–
calculation.
CB definition
–
DS11 definition
–
DS12 definition
–
DS13 definition
–
DS21 definition
–
Line1 definition
–
Line2 definition
–
Line3 definition
–
Definition of CT position
–
Current zero ampere control with CB
–
condition
CH use definition
–
CH name definition
–
Bay device selection
–
Coupler No. definition
–
First defined zone for forward protection
–
Second
defined
zone
–
protection
Third
defined
zone
–
protection
Defined zone for reverse protection
–
CH's current is unused in the DIF zone
–
calculation.
CB definition
–
DS11 definition
–
DS12 definition
–
DS13 definition
–
DS21 definition
–
Line1 definition
–
6F2S1923 (0.03)
Default
BIO#6
Off
(Blank)
Non
1
Non
for
forward
Non
for
forward
Non
Non
Non
Non
Non
Non
Non
Non
Non
Non
Non
Pos1
Off
Off
(Blank)
Non
1
Non
for
forward
Non
for
forward
Non
Non
Non
Non
Non
Non
Non
Non
Non
GRB200C (Replica)