Hardware settings of CBP REPRICA (Function ID: 4F0B01)
Setting item
Settings in
SubUnit#1
SubUnit#1
Sub1 VCT#1
Sub1 VCT#2
Sub1 IO#1
Sub1 IO#2
Sub1 IO#3
Sub1 IO#4
Sub1 IO#5
Sub1 IO#6
Sub1 IO#7
Sub1 IO#8
Settings in
SubUnit#2
SubUnit#2
Sub2 VCT#1
Sub2 VCT#2
Sub2 IO#1
Sub2 IO#2
Sub2 IO#3
Sub2 IO#4
Sub2 IO#5
Sub2 IO#6
Sub2 IO#7
Sub2 IO#8
BI1-2_CH1
BI3-4_CH1
BI settings for
CH1
BI5-6_CH1
BI7-9_CH1
BI1-2_CH2
BI settings for
BI3-4_CH2
CH2
BI5-6_CH2
BI7-9_CH2
~
BI1-2_CH24
BI settings for
BI3-4_CH24
CH24
BI5-6_CH24
BI7-9_CH24
Note: Setting items in CH4to CH23 are omitted, but the similar rules are applied.
Un
Range
its
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
NoUse / Use
DS12 / DS13 / DS21
/ CB / Other
DS11 /Other
DS12 / DS13 / DS23
/ CB / Other
CBF_Start / Other
DS12 / DS13 / DS21
/ CB / Other
DS11 /Other
DS12 / DS13 / DS23
/ CB / Other
CBF_Start / Other
DS12 / DS13 / DS21
/ CB / Other
DS11 /Other
DS12 / DS13 / DS23
/ CB / Other
CBF_Start / Other
- 29 -
Contents
Switch to use SubUnit#1 or not
Switch to use VCT#1 in SubUnit#1 or not
Switch to use VCT#2 in SubUnit#1 or not
Switch to use Sub1_IO#1 or not
Switch to use Sub1_IO#2 or not
Switch to use Sub1_IO#3 or not
Switch to use Sub1_IO#4 or not
Switch to use Sub1_IO#5 or not
Switch to use Sub1_IO#6 or not
Switch to use Sub1_IO#7 or not
Switch to use Sub1_IO#8 or not
Switch to use SubUnit#2 or not
Switch to use VCT#1 in SubUnit#2 or not
Switch to use VCT#2 in SubUnit#2 or not
Switch to use Sub2_IO#1 or not
Switch to use Sub2_IO#2 or not
Switch to use Sub2_IO#3 or not
Switch to use Sub2_IO#4 or not
Switch to use Sub2_IO#5 or not
Switch to use Sub2_IO#6 or not
Switch to use Sub2_IO#7 or not
Switch to use Sub2_IO#8 or not
Set connected device using BI1–BI2 at CH1
Set connected device using BI3–BI4 at CH1
Set connected device using BI5–BI6 at CH1
Set connected device using BI7–BI9 at CH1
Set connected device using BI1–BI2 at CH2
Set connected device using BI3–BI4 at CH2
Set connected device using BI5–BI6 at CH2
Set connected device using BI7–BI9 at CH2
Set connected device using BI1–BI2 at CH24
Set connected device using BI3–BI4 at CH24
Set connected device using BI5–BI6 at CH24
Set connected device using BI7–BI9 at CH24
6F2S1923 (0.03)
Default
setting
value
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
NoUse
CB
DS11
DS12
CBF_Start
CB
DS11
DS12
CBF_Start
~
CB
DS11
DS12
CBF_Start