B00: RF ADJUST
RF ADJUST subscreen
Item
SUPER
No.
DISP.
P00 DVCPRO 50M ADJUST
Q00 DVCPRO 25M ADJUST
R00 DV ADJUST
DVCRRO 50M ADJUST subscreen
Item
SUPER
No.
DISP.
P-1
REC ADJUST
P-2
PB ADJUST
P-3
RP ADJUST
P-4
DEFAULT
DVCRRO 25M ADJUST subscreen
Item
SUPER
No.
DISP.
Q-1
REC ADJUST
Q-2
PB ADJUST
Q-3
RP ADJUST
Q-4
DEFAULT
Adjustment for DVCPRO50 (50 Mbps)
Adjustment for DVCPRO (25 Mbps)
Adjustment for DV
Adjustment of the recording system for DVCPRO50 (50 Mbps)
Adjustment of the playback system (PB head) for DVCPRO50 (50 Mbps)
Adjustment of the playback system (RP head) for DVCPRO50 (50 Mbps)
LOAD/SAVE of the factory default adjustment values/initial values LOAD operation
• Perform operation in regard to the adjustment values for DVCPRO50 (50 Mbps).
Operation:
1. Move the cursor to P-4: DEFAULT and press "set" button.
2. Turn the search dial button and move the cursor to the desired operation item.
SAVE ...
Save the present set values as the factory default values.
LOAD ...
Load the saved factory default values as the present set values.
(When SAVE operation has not been performed, the initial values
will be loaded.)
INIT LOAD ... Load the initial value (which designer decide) as the
present set values.
3. When the SET button is pressed, the selected operation will be performed and it
will return to the item setting screen.
When the MENU button is pressed, no operation will be performed and it will return
the item setting screen.
Adjustment of the recording system for DVCPRO (25 Mbps)
Adjustment of the playback system (PB head) for DVCPRO (25 Mbps)
Adjustment of the playback system (RP head) for DVCPRO (25 Mbps)
LOAD/SAVE of the factory default adjustment values/initial values LOAD operation
• Perform operation in regard to the adjustment values for DVCPRO (25 Mbps).
Operation:
1. Move the cursor to Q-4: DEFAULT and press "set" button.
2. Turn the search dial button and move the cursor to the desired operation item.
SAVE ...
Save the present set values as the factory default values.
LOAD ...
Load the saved factory default values as the present set values.
(When SAVE operation has not been performed, the initial values
will be loaded.)
INIT LOAD ... Load the initial value (which designer decide) as the
present set values.
3. When the SET button is pressed, the selected operation will be performed and it
will return to the item setting screen.
When the MENU button is pressed, no operation will be performed and it will return
the item setting screen.
INF-36