Technical Specifications Of Rack-Mounted Housing - Siemens SIPROCESS GA700 Compact Operating Instructions

Continuous gas analysis
Hide thumbs Also See for SIPROCESS GA700:
Table of Contents

Advertisement

Technical specifications
9.2 General technical specifications
9.2.2

Technical specifications of rack-mounted housing

Table 9-2
Rack-mounted housing: General technical specifications
General
Installation position
Weight
Degree of protection
Electrical characteristics
Auxiliary power supply
Power consumption
EMC interference im‐
munity (electromag‐
netic compatibility)
during operation:
Electrical safety
Transient protection
Power unit cable
Electrical inputs and outputs
Digital outputs (DO)
Digital inputs (DI)
Service interface (rear)
Service interface (front)
84
Horizontal
Approx. 8.5 kg
IP20 according to EN 60529
with one and/or two OXY‐
MAT 7 / ULTRAMAT 7 units
with one or two CALOMAT 7
units
8, with changeover contacts, parameters can be freely assigned, e.g. for measuring range
identification; max. load: 24 V AC/DC/1.7 A (total load for all 8 relay outputs in continuous
operation max. 160 W), isolated, non-sparking
8, designed for 24 V, isolated, freely parameterizable, e.g. for autoranging
Ethernet RJ 45, 100 Mbps
Ethernet RJ 45, 100 Mbps
100 to 240 V AC (nominal range of use 85 to 264 V)
50 to 60 Hz (nominal range of use 47 to 63 Hz)
Max. 280 VA
in accordance with the standard requirements of NA‐
MUR NE21 (05/2006) and EN 61326-1 (2013)
in accordance with standard requirements EN 61326-1 (2013)
in accordance with EN 61010-1, overvoltage category II
It has to be ensured that the transient protection is set to a value that
does not exceed 140% of the measured peak voltage value at the
device power supply connectors.
Cable diameter: max. Ø 10 mm (3/0 AWG)
Core cross-section: max. 3 x 2.1 mm
Compact Operating Instructions, 01/2022, A5E35134047-11
(14 AWG)
2
Devices in explosion-proof design