Failure Code [D1Eskb] (Ladder Lower Solenoid Output Ground Fault) - Komatsu WA900-3E0 Shop Manual

Hide thumbs Also See for WA900-3E0:
Table of Contents

Advertisement

Troubleshooting by failure code

Failure code [D1ESKB] (Ladder lower solenoid output ground fault)

Failure code [D1ESKB] (Ladder lower solenoid output ground fault)

Action level
Failure code
E01
D1ESKB
Detail of failure
Overcurrent flows when driving ladder LOWER solenoid, so solenoid is not energized.
q
Action of con-
Stops ladder lower solenoid output.
q
troller
Stops driving ladder LOWER solenoid until its power supply is turned off.
q
Problem on
Ladder cannot be lowered.
q
machine
Ladder can be moved to storage and boarding positions by using emergency release valve.
q
Related infor-
Output signal to ladder LOWER solenoid can be checked with monitoring function.
q
mation
Code: 40992 "D-OUT-19" (ON: 1, OFF: 0)
No.
Cause
Open circuit in wiring harness
1
(wire breakage or defective con-
tact of connector)
Ground fault in wiring harness
2
(short to ground circuit)
3 Defective ladder LOWER solenoid
4 Defective power ladder controller
40-20
Failure
Ground fault in ladder LOWER solenoid
Procedure, measuring location, criteria and remarks
1. Turn starting switch to OFF position.
2. Disconnect PC0 and PLDW.
Between PC0 (female) (20) and PLUP (female) (1)
Resistance
Between PC0 (female) (40) and PLUP (female) (2)
1. Turn starting switch to OFF position.
2. Disconnect PC0 and PLDW.
Between PC0 (female) (20) and (40)
Resistance
Between PC0 (female) (20) and ground
1. Turn starting switch to OFF position.
2. Disconnect connector PLDW.
Between PLDW (male) (1) and (2)
Resistance
Between PLDW (male) (1) and ground
If no failure is found by check on causes 1 to 3, power ladder controller may be
defective. (Since this is an internal defect, troubleshooting cannot be per-
formed.)
4 0 - 2 0
Max. 1 z
Max. 1 z
Min. 1 Mz
Min. 1 Mz
15 to 30 z
Min. 1 Mz