Failure Code [Dhslma] Blade Lower Ppc Press Sensor Abnormality - Komatsu Galeo PC138US-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for Galeo PC138US-8:
Table of Contents

Advertisement

SEN02465-01

Failure code [DHSLMA] Blade lower PPC press sensor abnormality

User code
Failure code
DHSLMA
Contents of
• Signal voltage of blade lower PPC pressure sensor circuit is below 0.3 V or above 4.5 V.
trouble
Action of
• Fixes blade lower PPC pressure at 0 MPa {0 kg/cm
controller
• If cause of failure disappears, system resets itself.
Problem that
• Automatic decelerator cannot be reset.
appears on
• Blade lower performance lowers.
machine
a If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor
will be broken. Accordingly, take extreme care when checking.
Related
• Blade lower PPC pressure can be checked with monitoring function.
information
(Code: 07107 Blade lower PPC pressure)
• Method of reproducing failure code: Turn starting switch ON or start engine.
Defective 5V sensor power
1
supply 1 system
Defective blade lower PPC
2
pressure sensor (Internal
defect)
Possible causes
and standard
Disconnection in wiring har-
value in normal
ness (Disconnection in wiring
3
state
or defective contact in con-
nector)
Ground fault in wiring har-
4
ness (Short circuit with GND
circuit)
Hot short (Short circuit with
5
24V circuit) in wiring harness
6 Defective pump controller
26
Blade lower PPC pressure sensor abnormality
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
If failure code [DA25KP] is also displayed, carry out troubleshoot-
ing for it first.
a Prepare with starting switch OFF, then turn starting switch ON
Between (3) – (1)
Between (2) – (1)
If voltage is abnormal, replace blade lower PPC pressure sensor
with another PPC pressure sensor and check failure code. (If "E" of
failure code goes off at this time, blade lower PPC pressure sensor
is defective.)
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between C01 (female) (18)
– P11 (female) (1)
Wiring harness between C01 (female) (51)
– P11 (female) (2)
Wiring harness between C01 (female) (9) –
J07 – P11 (female) (3)
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between C01 (female) (51)
– P11 (female) (2)
a Prepare with starting switch OFF, then turn starting switch ON
Wiring harness between C01 (female) (51)
– P11 (female) (2)
If causes 1 – 5 are not detected, pump controller may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.)
2
} and continues control.
or start engine and carry out troubleshooting in each case.
P11
Power supply
ing without turning starting switch ON.
ing without turning starting switch ON.
and carry out troubleshooting.
40 Troubleshooting
Voltage
4.5 – 5.5 V
Signal
0.3 – 4.5 V
Resis-
tance
Resis-
tance
Resis-
tance
Resis-
tance
Voltage
PC138US, USLC-8
1
Max. 1 z
Max. 1 z
Max. 1 z
Min. 1 Mz
Max. 1 V