Failure code [DW91KA] Travel junction sol discon

User code
Failure code
DW91KA
Contents of
• When output to travel junction solenoid was turned ON, disconnection was detected in circuit.
trouble
Action of
• None in particular. (Since no current flows, solenoid does not operate.)
controller
• If cause of failure disappears, system resets itself.
Problem that
appears on
• Machine is not steered easily during travel.
machine
• Operating condition of travel junction solenoid can be checked with monitoring function.
Related
(Code: 02300 Solenoid 1)
information
• Method of reproducing failure code: Start engine + Steer machine with right and left travel levers.
Defective travel junction
1
solenoid (Internal disconnec-
tion)
Possible causes
Disconnection in wiring har-
and standard
ness (Disconnection in wiring
2
value in normal
or defective contact in con-
state
nector)
3 Defective pump controller
Circuit diagram related
36
Travel junction solenoid system disconnection
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshoot-
a Prepare with starting switch OFF, then carry out troubleshoot-
Wiring harness between C02 (female) (110)
– V04 (female) (2)
Wiring harness between C02 (female) (115),
(117), (120) – V04 (female) (1)
a Prepare with starting switch OFF, then carry out troubleshoot-
Between (110) – (115), (117),
ing without turning starting switch ON.
V04 (male)
Between (1) – (2)
ing without turning starting switch ON.
ing without turning starting switch ON.
C02 (female)
(120)
40 Troubleshooting
1
Resistance
20 – 60 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resistance
20 – 60 z
PC138US, USLC-8