SEN02716-00
Removal and installation of pump
controller assembly
Removal
k
Disconnect the negative (–) terminal of the
battery beforehand.
1.
Remove cover (1).
2.
Remove cover (2).
3.
Remove duct (3).
4.
Remove cover (4).
8
5.
Disconnect wiring (5) and (6).
a Pull each connector lever (a) and (b)
1
inward.
6.
Remove 4 mounting bolts (7) and 2 mounting
bolts (8), and remove pump controller assem-
bly (9).
Installation
Carry out the installation in the reverse order of
q
removal.
50 Disassembly and assembly
PC138US, USLC-8